显示标签为“fan motor”的博文。显示所有博文
显示标签为“fan motor”的博文。显示所有博文

2014年11月18日星期二

Switch function three


gost motor 7.5kw

Specifications
1. effiency: IE2 and IE1 
2. 20 years manufacturing experience 
3. 12 months guarantee 

4. low noise and vibtration
Switches can be carried out at the same time between multiple ports for data transfer. Each port can be regarded as independent segment, connected to the network device alone enjoy full bandwidth, do not need to compete with ANP gost motor other equipment to use. When the node A to node D send data, node B can send data to the node C at the same time, and it all has two transmission network bandwidth, have their own virtual connection. If used here is 10 MBPS Ethernet switch, electric motor price the switch at this moment in circulation is equal to 2 x 10 MBPS = 20 MBPS, while using 10 MBPS Shared HUB, a HUB in circulation will not exceed 10 MBPS. Anyhow, switch is a kind of based on MAC address recognition, can finish the package forwarding packets function of network equipment. Switches can "learn" MAC address, and keep it in the internal address table, Single phase motor through between the originator of a data frame and target receivers to establish a temporary switching path, make the data frame directly by the source address to reach the destination address.

2014年11月9日星期日

Working principle of the circuit

 Stator Motors Rotor 
Specifications
1. 20 years manufacturing experience
2. competitive price,high quality
3. Brand Name: FUJIAN DONGFENG MACHINERY ELECTRICAL LIABILITY CO., LTD

Indoor machine after joining 220 v ac voltage, wire by T301 added to the socket cN5, zero line from the first (3) feet, FU300, T301 cN4 socket to socket cN5, get 220 v ac power transformer primary, secondary 13 v ac voltage, D204, D205, D206, D207, C214 rectifier filter into the 12 v dc voltage. The voltage all the generator set spare parts way to ICl02, miniature relay SW301 ~ SW305 and buzzer power supply, a path V202, C106 voltage filter + 5 v voltage ICl (47 c862an - GC51) power supply. ICl03 (3) feet will reset signal into ICl 20 reset end, ICl began to work. When the infrared receiver to receive after the refrigeration, by ICl 46 feet to the CPU, 31 feet a pulse output level, electric vehicle motor the buzzer rang once, to alert the user. At this point, the reader set temperature and 38 feet within the operations of the indoor temperature www.dongfeng-motor.com of the indoor temperature sensor test to compare.


Y2 series electric motor wholesale
Specifications
1. effiency: IE2 and IE1 
2. 20 years manufacturing experience 
3. 12 months guarantee 
4. low noise and vibtration 

5. AC Voltage: 220V/380V, 380V/660V,400V/690V,220V/400V

 if the temperature is higher than the room temperature, the cPu will not perform refrigeration instructions; If the set temperature is lower than the room temperature, the cPu to execute commands refrigeration. If wind speed setting of high speed gear, Icl 12 feet, output level for the first 7 ICl02 feet, inverter output low level ICl02 first attending foot, SW303 electricity and, on the high-grade indoor machine work. At this moment, Icl01 first (2) feet ac motor output high level, after the first 5 feet inverting ICl02 from 12 feet output low level, make SW301 absorption, on the offer outdoor 220 v ac power. ICl to seg signal refrigeration operation at the same time, ICl01 52 feet output high level, light green light is LED3 operation. After the user starts the wind on the remote control function, Icl is the first 4 feet high output level for the first 3 feet, inverter Icl02 Icl02 14 feet output low level, SW305 to suck, synchronous motor running, realize the three-dimensional supply function.

2014年10月28日星期二

Trapezoidal wave type in phase one

 Brushless motor driven trapezoidal wave control mode of the frame. motor parts Here a PI control circuit is used to to control current. We use the actual measurement of the current demand and current comparison, get a deviation signal. This deviation signal through the integral and magnified and produce an output correction value, the deviation value is used to reduce the error. This spare parts produced by P - I control loop correction value through PWM setting, then to provide output bridge road. The purpose of this procedure is to ensure that any of the current in the coil remained stable state. Change of phase current control part without any contact. Motor hall sensor in fan motor the wholesalemotor.blogspot.com position signal is used to choose which a pair of coil way need to pass to current corresponding to the output of the bridge, while the other bridge road keep current status. Current sensing circuit is mainly used to real-time current of electric coil, and the feedback signals to the current control loop.

2014年8月27日星期三

Frequency conversion air conditioning really save electricity?


First,the frequency conversion air conditioning really save electricity,frequency conversion air
conditioning energy saving principle 1.The principle of frequency conversion air conditioning is air conditioning adopted more advanced 220v ac electric motor stechnology,the startup voltage is small,but under the condition of low voltage and low temperature start,that www.dongfeng-motor.com in some areas due to the low voltage instability or winter indoor temperature and air conditioning,it is hard to start a certain improvement effect.Due to realize the stepless variable speed compressor,it can also adapt to more widespread refrigeration and heating demand.2.Simply put on the principle of frequency conversion air conditioning is in the structure of conventional permanent magnet motors for saleair conditioning increased by a frequency converter.

The heart of the air conditioning compressor,its speed directly affects the efficiency of the use of air
conditioning,frequency conversion air conditioning inverter is used to control and adjust the
compressor speed control system,make it always in the best state of rotational speed,thus,improve the
energy efficiency ratio is larger than that of conventional air conditioning energy saving 20% ~
30%.Second,the frequency conversion air conditioning really save electricity,high frequency operation
more efficient 1.The frequency conversion air conditioning in addition to just boot with high
frequency operation,other operating at low frequency,most of the time consumed power is far less than the air conditioning that decide frequency.Compressor is Motor vehicle a large energy consumption of air conditioning,its rated output accounted for about 90% of the air conditioning machine power,the other 10% for fan motor and other electric parts;The frequency conversion air conditioning compressor
efficiency is higher than the ordinary air conditioning that decide frequency compressor.2.The number of frequency conversion air conditioning open stop is much lower than that of the air conditioning that decide frequency switching frequency,the air conditioning that decide frequency boot will consume a lot of energy.Ac frequency conversion air conditioning than the air conditioning that decide frequency to save electricity by 30%,while dc frequency conversion air conditioning power saving 50%.

2014年8月14日星期四

A,the structure of the three-phase asynchronous motor


A,the structure of the three-phase asynchronous motor,is made up of stator,rotor and other accessories. 1,the stator core Part of motor magnetic circuit,and placed on the stator winding.Structure:the stator iron core by 0.35 ~ 0.5 mm thick surface is commonly insulating layer of silicon steel sheet coining,overlying and become,within the core of the circle has a uniform distribution trough,which embedded in the stator winding.Trough the stator core has the following kinds:Semi-closed type slot:the efficiency and power factor of three phase generator the motor is higher,but the winding wire and insulation are more difficult.Commonly used in low-voltage motor.Half-open mouth slot:can put molding winding embedded,commonly used in large and medium-sized low-voltage motors.The so-called forming the windings can be treated with insulation in advance and then into the slot.Open rack slot:to put molding winding embedded,insulation method is convenient,mainly used in high voltage motor.2,the stator winding Access is the circuit part of the motor,three-phase alternating current (ac),to produce a rotating magnetic field.Structure:by the three in the space between 120 ° Angle,said arrangement can be connected with the same structure of the winding,the winding of the coil embedded respectively according to certain rule In electric motor laminations the stator slot.

The main of the stator winding insulation project has the following three:(guarantee between the
conductive part of the winding and iron core reliable insulation and reliable insulation between the winding itself).(1) of insulation:the whole and the stator winding insulation between the stator
core.Between diction and insulation:each phase of the stator winding insulation.(3) the turn-to-turn
insulation:each phase of the stator winding turn-to-turn insulation each wire.The motor terminal box
wiring:Motor terminal box has a wiring board,six of the three-phase winding thread in two rows,up and
down and from left to right are the three most wiring pile arrangement of the no.1 (U1),2 (V1),3
(W1),pile bottom three wiring from left to right to arrange the Numbers for 6 (W2),4 (U2),5 (V2),the
three phase windings into stars Connection or delta connection.All manufacturing and maintenance
shall be according to the serial number.3,stand Function:fixed ends and to support the rotor,stator
core and plays a role of protection,heat dissipation and so on.Structure:stand for cast iron
parts,usually large asynchronous motor base plate is commonly used in welding,micro motor frame
adopts cast aluminum.Enclosed machine stand outside Face with radiating rib to increase the cooling
area,protected on both ends of the frame of the motor end cover open vent,make motor inside and
outside air electricalmotor1.blogspot.com convection,can be directly to facilitate heat dissipation.

The cause of the slow speed motor load runtime


1),2) the power supply voltage is too low,squirrel cage rotor broken bar 3) group,coil,or coil
short-circuit point 4),the coil or coil group has 5),the reverse phase winding 6) 7),overload,wound
rotor type a wholesalemotor.blogspot.com phase break 8),wound rotor type motor starting rheostat poor contact 9),brush and slip ring poor contact 2.The motivation of the voice is not the cause of the normal during operation 1),the phase of the stator and rotor brush 2),3),the rotor rubbing rotor blades touch shell 4) insulation paper,bearing the lack of oil 5),the motor with sundry 6),motor with buzz two phase operation 5.The motor shell charged reasons: 1),2) the power cord and ground wire to make wrong,be affected with damp be affected with damp,motor winding insulation aging reduce insulation performance (3),4) lead and junction box body contact,local winding Insulation Motor vehicle damage to wires touch shell relaxation stabbed 5),core wire 7) 6),grounding line failure,damage to the wiring board,or on the surface of the oil too much Excessive sparking 6.Winding rotor slip ring 1),2) slip ring surface dirt,brush pressure is too small (3) 4) jams,brush in the brush,brush deviating from the neutral position 7.The motor temperature rise too high or the reason of rotor balancing machine smoking 1),2) power supply voltage is too high or too low,overload 3),4),the stator winding single- phase running ground 5),6) bearing damage or bearing is too tight,the stator winding Group of turns or interphase short circuit 7),environmental temperature 8),motor fan duct not free or damaged.