2014年10月22日星期三

Multimeter use the matters needing attention

(1) before using the multimeter,should be "mechanical zero",namely when no power being measured,the multimeter pointer refers to in the position of zero voltage or zero current.(2) in the process of using the multimeter,can't use hand to touch pens and metal parts,so that on the one hand can guarantee the accuracy of the measurement,on the other asynchronous motor hand also can generator generator set guarantee personal safety.(3) in the measurement of a certain power,not in the measurement of shift at the motor vehicle same time,especially in measuring high voltage and large current,more attention should be paid to.Otherwise,can make the multimeter.For shifting,should first disconnect pens and,after the shift to measure again.(4) multimeter when use,must be placed,so as not to cause the error.At the same time,but must pay attention to avoid the influence of external magnetic field on the multimeter.(5) the multimeter after use,should be the biggest block switch in the ac voltage.acmotortrading.blogspot.com If you don't use for a long time,also should be multimeter out internal battery,so as to avoid battery corrosion of other devices in the table.

2014年10月21日星期二

PLC control two pump start-up failure solutions to problems


Situation:in the double liang steam double-effect lithium bromide absorption air-conditioning unit,the use of omron PLC (PA204S C200HE-CPU42,power supply) to control the start of two pumps. When,in turn,start the two pumps,often led to the suspension of the power of the PLC,thus stop running program.Second,the detection of 1,use the meter to measure the voltage electric motor 12v 500w waveform of two pump ordinal startup PLC power PA204S ac voltage of the power supply change found:when did not start the electrical motor 12v 1000w pump,the voltage of the power supply is normal,when start the two pumps,instantaneous fell to the power supply voltage of 184 v,184 v and the duration of the above 25 ms,PLC to stop working,and to determine the effect of pump power of PLC.2,in order to solve this problem,respectively for the following tests: A) driving the pump first,delay around 10 s to start small pump,power supply voltage drop to about 190 v,the instructions first,pump makes instantaneous voltage drops,later start small pump,affect smaller,but it need to modify the PLC program.

B) because the pump power supply is turned by high tension line through a transformer,transformer capacity,can be considered a large capacity of transformer,may make the pump will be smaller influence on the PLC power supply voltage.C) in the PLC power supply termination a large capacitance,but the effect is not obvious.D) finally in one power supply transformer converted by a 220 v power supply to PLC,found that even in the start two pumps at the same time,PLC power supply voltage drop is only about 204 v,204 v,the can.Conclusion:as a result acmotortrading.blogspot.com of the PLC power supply is supplied with water pump in the same way,and the plant's transformer capacity is small,so in the start two pumps,caused the PLC power supply voltage drops below 85% of rated voltage,and duration of more than 10 ms,resulting in PLC detected power interruption,stop working. So the advice from the transformer converted one by one in the 220 v power to separate for PLC,which can solve the problem.