Three-phase asynchronous motor open phase running fault


Lack of phase operation reason (1) the star connection broken a phase power supply.(a) as shown in figure 8,when the motor is running,for some reason,there is a phase circuit (such as W phase winding in the L3 disconnect),then in the W phase winding current,two phase winding become series relationship between rotor and stator U and V,pick up on the 380 V voltage,while two flows winding the same current,which is lack of phase operation.The motor still can continue to operate,but the work of the two phase winding,on both ends of each phase voltage is 190 v (phase voltage 220 v) in normal working conditions.Due to the phase voltage is reduced,rotating magnetic flux are reduced accordingly.But the load constant,the output torque of the motor is constant,so the stator current will increase.In addition,according to the analysis of power Angle of the normal work of the motor,three-phase winding average burden of power will increase,the winding current must be increased.In short,a phase winding,when the power is the single phase asynchronous motor burden of the remaining two phase winding.At this point in the winding current value is greater than the motor overload current,but smaller than short circuit current.

(2) delta connection broken a phase power supply.(b) as shown in figure 8,if L3 disconnect,then pick up the entire winding between two phase,which is lack of phase operation.Although the three-phase windings are working at this time,but they ac geared motor have not symmetric winding,but M phase winding facies V phase winding in series,and then winding parallel with U.In this case,the current in the winding,power is not tight and normal power current,power is different at work.Two branch current is not balanced.The theory and practice have proved that winding to delta connection,once broken a photograph,can form large circulation inside the motor winding,a very short time will burn out motor winding,the harm than y connection of motor open phase running is more serious.(3) delta connection within a phase of winding circuit.(c) as shown in figure 8,when the two phase of the motor winding form v-shaped connection,this connection,the starting torque is too small.The original ban motor starting; The motor is running,and the cut-off current is 0,is not to do work,the rest of the two phase winding load is aggravating,current increases,increased winding temperature rise.

2014年8月31日星期日

Motor startup mode


Include:motor startup mode,auto voltage reducing total pressure direct start starting,y-delta
starting,soft starter,inverter.Total pressure directly starting:At both capacity and load of power
grid allows total pressure directly under the condition of starting,can consider to use the direct
starting.Advantage is that control is convenient,simple maintenance,and more economic.Mainly used in ac geared motor small power motor starting from saving energy point of view,should not be greater than 11 kw motor by this method.Auto voltage reducing starting:use autotransformer tapped the reduced pressure,can adapt to the needs of different load starting,and can get a bigger starting torque,is a kind of is often used to starting decompression of the large capacity motor starting.Its the biggest advantage is
starting torque is bigger,when the tap at 80%,starting torque can be up to 64% of direct starting.And can adjust the starting torque by tapping.Are still widely used.

Y-delta starting:for normal operation of the stator winding of delta connection of squirrel-cage asynchronous motor,if at the time of starting the stator windings into star,waiting for start to end to connect into a triangle,can reduce the starting current,to reduce its impact on the grid.Such starting way is called star triangle decompression starting,or simply the star delta starter (y - delta starter).Using star delta starter,starting current is only according to the delta connection directly when starting a third of the original.If direct starting when the starting current to 6~7 meter,ie in star triangle is
starting,the starting current is 2~2.3 gasoline generator spare parts times.This means using star delta starter,starting torque is reduced to the original starting directly based on the delta connection when a third.Suitable for the occasion of no load or light load starting.And compared with any other decompression starter,its structure is the most simple,the price is the cheapest.In addition,a further advantage of star triangle starting way,namely when the load is lighter,can let the motor run in y connection.

At this point,the rated torque and load can match,this can make the motor efficiency is improved,and save the electricity consumption.Soft starter:this is the phase shift voltage regulating principle of SCR is used to realize the regulating of the motor starting,it is mainly used for motor starting
control,starting effect Motor vehicleis good but the cost is higher.By using thyristor,thyristor harmonic interference is larger at work,have a certain influence on power grid.Additional power fluctuations will also affect the thyristor conduction,especially how thyristor devices in the same power network.So the thyristor failure rate is higher,because involving power electronic
technology,therefore,taller also to the requirement of maintenance technicians.Inverter,inverter is
the highest technical content of modern motor control field,the most complete control function,the best control effect of motor control device,it is by changing the frequency of the power grid to adjust the rotation speed and torque of the motor.Because of involving power electronic technology,computer technology,so the cost is high,too high to the requirement of maintenance technicians,mainly used in need speed and the field of high speed control requirements.

2014年7月22日星期二

Double speed three phase asynchronous motor winding classification

Double speed three phase asynchronous motor winding classification A single layer winding: Single-
layer windings is each embedded in the stator slot only buy a coil winding, on the edge of
effectively, so it only total coil motor half of the total number of slots. The advantages of the
single layer winding is winding coil number less process is simple; Utilization of the interlayer not
denied because trough increase; Single layer does not happen and breakdown failure, etc. Drawback is
the winding of the electromagnetic wave shape is not ideal, motor iron ac synchron motor loss and noise are large and starting performance also is a bit poor, so the single layer winding asynchronous motor only commonly used for small capacity. In accordance with the single layer winding coil shape and arranged termination local arrangement is different, can be divided into chain winding, cross chain,
concentric windings and intersection concentric winding winding types, etc. 1 chain chain windings
is by having the same shape and width of single coil components, due to its winding ends each coil
like set up the link of the name. Should pay special attention to single chain winding of the coil
pitch necessary for odd number, otherwise will not be able to arrange the winding arrangement. As
per each phase 2 cross chain winding slot number nine is greater than 2 odd number will not be able
to arrange the chain winding arrangement, at this time will need to use the intersection with single
and double coil winding. 

Three concentric winding in the same group of extremely all coil around the same circle. When each ac synchronous motorphase slot number per level 4 Q is greater than 2 even can adopt the form of cross
concentric winding. The advantages of single-layer concentric winding and cross concentric winding
for winding, is relatively simple, embedding a long use wire end of faults is too much. Now except
for useful in small capacity of 2, 4 pole motor, is now rarely use this winding form. Double
cascading winding Single and double layer composite winding Star connection relationship with the
Angle joint When the star of by change Angle: the original star connection wire diameter total
cross-sectional area divided by 1.732 is equal to the Angle of the wire diameter total cross-
sectional area. The Angle of by change star: when the original Angle joint line diameter when the
total cross-sectional area multiplied by 1.732 is equal to the star connection wire diameter of the
total cross-sectional area. The difference of star connection with nature Angle joint When star
connection line voltage equals 1.732 times the phase voltage, phase current is equal to the line
current. Angle joint when the phase voltage is equal to the line voltage and line current is equal to
the phase current of 1.732 times. With the power of the motor, when the star connection, wire
diameter thick, less number of turns, the Angle joint, fine wire diameter, number of turns. When the
Angle joint sectional area is 0.58 times of star connection. When the Angle joint line diameter when
the total cross-sectional area divided by 0.58 is equal to the star connection wire diameter of the
total cross-sectional area. When the star connection wire diameter total cross-sectional area
multiplied by 0.58 is equal to the Angle of the wire diameter when total cross-sectional area)
cross-section of wire diameter calculation formula: cross-sectional area S = square multiplied by
0.785 is the diameter of the motor internal connection with salient pole and ordinary pole, salient
pole and ordinary pole is determined by the design properties of the www.facebook.com/dongfeng.motor motor can not be changed motor no-load current coefficient calculation.