2014年8月8日星期五

Classification of motor

Ac motor Asynchronous motor Y series (low voltage,high voltage,frequency,electromagnetic brake) JSJ series (low voltage,high voltage,frequency,electromagnetic stator brake) Synchronous motor TD series TDMK series Dc motor Common dc motor Z2 series New generation of Z4 series A dedicated dc motor ZTP railway motor ZSN cement rotary kiln The use of the motor and control is very convenient and small electric motors has since starting,acceleration,braking,reverse and stopper live ability,can meet various operation requirements; The work of the motor High efficiency wholesalemotor.blogspot.com and no dust,smell,polluting the environment,the noise is small.Because of its series of advantages,so in industrial and agricultural production,transportation,national defense,business Industry
www.facebook.com/guohong.trading and household appliances,medical electrical equipment and so on various aspects widely used.

2014年8月7日星期四

made in china three phase ac high efficiency electric motor

Three-phase asynchronous motor winding split phase is by what law? 6 72 slot 2 road,two-way parallel 6 pole motor,double winding coil 18 groups,each group of four coil,electric vehicle motor round well after this,the head and tail,distinguish each group with any group as the starting,every two groups take a group for the same phase of phase,i.e.,1,4,7,10,13,16 group for the same phase,namely W phase,and then take head line 1 group,four groups take tail line,7,10,13,16,all together,as the ultimate W1,then 1 tail 4 head 7 tail 10 13 tail 16 head caught together as the ultimate wholesalemotor.blogspot.com W2,such,can grasp the whole W phase succeeded,in the end,do the same thing,two head 5 end August 11 14 head and tail end catching together for U12 tail 5 first eight tail head 14 tail 17 head catching together for 11 U23 head tail 6 to 9 first 12 tail 15 first 18 tail caught together for V13 tail 18 June 12 head 15 tail first nine tail head catching together for V1 finally became a six chief,varnished after baking,W1 U1 V1,W2 U2 V2 according to the wiring seat on the marked 8500w gasoline generator up the line.

electric motor 20hp aluminum body

37 kw motor star triangle start,open,ac ac synchronous motor contactor,thermal after how to choose?37 kw motor current is about 69.8 A contactor LC1D choose 80 three phase generator or 80-8011 or LC1D - 9511 star with 6511 line LC1D6511 thermal relay with maximum of 72 line,Open in wholesalemotor.blogspot.com 100 a of the adjustable motor protector.

The working principle of the three-phase asynchronous motor

Working principle of the three-phase asynchronous motor is as follows:Symmetrical three phase winding ventilation with symmetrical three phase current,to produce a rotating magnetic field,magnetic field line cutting rotor winding,according to the principle of electromagnetic induction,rotor winding of e and I,rotor winding by the effect of electromagnetic force in the magnetic field,electromagnetic torque,which make the rotor rotation,the rotor output mechanical energy,drive the mechanical load.The rotor asynchronous motor rotating speed n Say again synchronous motor below:Synchronous motor as a generator running,the rotor winding with dc excitation at work,by external mechanical force to drive the rotor rotation,the direction of the n0 and torque T direction on the contrary,the stator of the induced emf (electromagnetic induction principle),and then the output voltage.Run-time synchronous motor for motor,rotor
electricalmotor1.blogspot.com winding with dc excitation at work,the stator three
phase alternating current (ac),to produce a rotating magnetic field,drive the rotor synchronous
rotation.Widely used three-phase asynchronous motor,but after running through a long time,can produce all kinds of fault,www.facebook.com/guohong.trading determine the cause of the
problem in time,the corresponding processing,is to prevent failure,ensure the normal operation of
equipment is an important work.Additional information:Generator in the form of a lot of,but its
working principle is motor lamination based on the law of electromagnetic induction
and electromagnetic force law.Therefore,the construction of the general principle is: use the
appropriate magnetic and conductive material electromagnetic induction of the magnetic circuit and
electric circuit with each other,to produce electromagnetic power,achieve the goal of energy
conversion.

Three-phase asynchronous motor starting method


Three-phase asynchronous motor is divided into squirrel-cage asynchronous motor and wound rotor asynchronous motor,the different structure,the boot method is different also,difference is very big.The start control lines.Squirrel-cage asynchronous motor full pressure start control circuit.Compared with the capacity of 8500w gasoline generatordc motor,asynchronous motor has small volume,light weight,the characteristics of moment of inertia of small.Therefore,in the asynchronous motor has been widely used in industrial and mining enterprises.In many industrial and mining enterprises,the number of squirrel-cage asynchronous motor to about 85% of the total number of electric drive equipment.Under the condition of the transformer capacity allows,squirrel-cage asynchronous motor should be as far as possible directly with full voltage start,can improve the reliability of control circuit,and can reduce electrical maintenance workload.The start of the three-phase asynchronous motor control line The three-phase asynchronous motor has simple structure,reliable operation,strong and
durable,cheap,convenient maintenance and so on a series of advantages.Most of the three-phase
asynchronous motor control line by the contactor,relay,knife switch,button,etc have a mix of contact
electrical appliances.One-way run electrical control circuit Main circuit QS by wholesalemotor.blogspot.com isolation switch,fuse FU,contactor KM normally open contacts,thermal relay FR heat element and motor of M.Control circuit by the starting button SB2,stop button SB1,contactor KM coil and normally open contacts,thermal relay FR normally closed contacts.Control circuit working principle is: 2,press the stop button to stop motor SB1,contactor KM coil electricity,its main contact and auxiliary contact are disconnected,motor from the power and stop operating.At this moment,even if loosen the stop button,because since the lock off contact,contactor KM coil will not electricity,motor will not start on its own. Only once rotor balancing machineagain press the starting button SB2,the motor will start running again.Unidirectional starter motor control circuit used to need only one direction of operation of small power motor control.For example small fan,water pump and belt conveyor and other mechanical equipment.This is one of the most commonly used,the most simple control circuit,can realize the automatic control of start-up and stop of the motor,remote control,frequent operation,etc.

2014年8月5日星期二

Nameplate parameters

Motor nameplate data and rating Model:the series of varieties,the performance of the motor,protective structures,such as rotor type product code.Rated power:it means the runtime on the output mechanical power rating of the motor shaft,unit KW electric vehicle motor or HP,1 HP = 0.736 KW.Voltage:directly to the line on the stator winding voltage (V),the motor has two kinds of Y and delta connection,the connection shall be consistent with connection of regulation of motor nameplates,to ensure that corresponding to the rated voltage.Current:motor under rated voltage and rated frequency,and the output power rating of the stator winding current of three-phase line Motor vehicle Frequency motor,which refer to connect the ac power frequency of 50 hz + 1 Chinese regulations Speed:motor under the rated voltage,rated frequency,rated load,motor speed (r/min) per minute;The 2 pole motor synchronous speed is 2880 / min.The duration of the work quota:refers to the motor running.Insulation class:the level of motor insulation materials,decided to allow temperature rise of the motor.Standard number:said design motor technical documents basis.Excitation voltage:refers to the synchronous motor excitation voltage (V) when the rated work.Field current:refers to www.dongfeng-motor.com the synchronous motor excitation current (A) when the rated work.

The motor brake specifications

The www.dongfeng-motor.com motor brake specifications 1,the brake torque:(1),0.5 N.m
(2),1 n. M.Test using a pointer type torque wrench,0 ~ 2 n. M 2,the rise of temperature of the
brakes:Products run on 115% of the wholesalemotor.blogspot.com rated
voltage,external temperature,maximum 120 degrees,use the outside temperature
detector,record,small electric motors different time periods for 24 to 48 hours.3,brake torque test and high temperature resistance high temperature dielectric strength testing:For 24 to 48 hours after making the products reached the highest temperature resistance torque value detection stator products,and test the insulation resistance,the parameter is: 1800 v / 2 ma,2 seconds.4,repetitive frequency brake products:120 times per minute.5,testing the brakes under normal working voltage of plus or minus 15% voltage is working correctly,and measure the torque and working current.