Motor fault check the motor fault processing, all kinds of methods of information on a variety. Some from the principle analysis, some experiences. (see electrical engineer) through experience, from the perspective of combining theory with practice to make specific analysis as follows. One, the motor starting motor not turn also perkins diesel generator no sound. Because the motor power supply or two phase or three phase winding circuit. First check whether there is a power supply voltage. Such as three-phase are no voltage, the circuit fault; If the three-phase voltage balance, fault in the motor itself. At this time to measure the resistance of the three-phase winding motor, find out the fault phase winding. Motor does not turn, but there are "buzzing" sound. Measure the motor terminal, such as three-phase voltage balance and the rating can be convicted of serious overload. Check step is, first remove the load, if the speed of the motor with a normal voice, which can determine overload or load mechanical part is faulty. If still do not turn, usable hand turn the motor shaft, if very tight or turn to be not moved, the three phase current measurement, such as three phase current balance, but may be larger than the motor part rating of the mechanical part of the motor was stuck on the motor oil shortage, bearing rust or damage is serious, end cover or oil cover too oblique, rotor and bore a collision sweep (also called bore). If you turn the motor shaft by hand to feel struggled with a certain way or at the sound of "scrape" cyclical, the chamber can be judged to sweep.